NACE-CIP2-001 Exam is a rigorous test that requires candidates to have a strong understanding of the principles and practices of corrosion control and coatings. To be eligible to take the exam, candidates must have at least two years of experience in the field and have completed the NACE-CIP1 (Coating Inspector Level 1) Exam. Candidates who pass the NACE-CIP2-001 Exam will be awarded the Coating Inspector Level 2 certification, which is recognized by employers and industry professionals worldwide.


NACE-CIP2-001 (Coating Inspector Level 2) Certification Exam is a globally recognized certification that validates the knowledge and skills of professionals in the field of corrosion control and protective coatings. Coating Inspector Level 2 certification is offered by the National Association of Corrosion Engineers (NACE) International, which is a leading organization dedicated to promoting corrosion control and prevention through education, certification, and networking.

 

NEW QUESTION # 54
Application of Thermal Spray Coatings requires:

  • A. No particular skills
  • B. The same skills as liquid coatings
  • C. Specialized skills supported by training and experience
  • D. The same skills as welding

Answer: C


NEW QUESTION # 55
Which surface preparation method uses a dilute acid solution to remove laitance and I roughen the concrete surface?

  • A. Sacking
  • B. Stoning
  • C. High-pressure water washing
  • D. Acid etching

Answer: D


NEW QUESTION # 56
A single component water borne acrylic coating cures by:

  • A. Oxidation
  • B. Co-Reaction
  • C. Solvent Evaporation
  • D. Coalescence

Answer: D


NEW QUESTION # 57
NACE Level 2 Inspectors have been authorized to perform:

  • A. Visual inspection and Non-destructive testing
  • B. Visual inspection only
  • C. All types of inspection without supervision
  • D. Visual inspection, Non-Destructive and Destructive testing

Answer: D


NEW QUESTION # 58
Surface preparation methods for Non-ferrous metals are:

  • A. The same as for Ferrous metals
  • B. Not required
  • C. Specific for each type of Non-ferrous metal
  • D. The same for all Non-FetT0us metals

Answer: C


NEW QUESTION # 59
When environmental enclosures are being used an inspector needs to be concerned about:

  • A. Lighting
  • B. a), b), and c)
  • C. Air changes
  • D. Structural integrity

Answer: B


NEW QUESTION # 60
When a coating is expected to be exposed to temperatures above 93C (200 F) the best choice would be:

  • A. Polyurea
  • B. Organic coatings
  • C. Inorganic Coatings
  • D. Latex

Answer: C


NEW QUESTION # 61
The most likely area of failure on a buried external pipeline coating is the:

  • A. Mainline coating
  • B. Ground bed
  • C. Field joint coating
  • D. Areas exposed to Ultra Violet light

Answer: C


NEW QUESTION # 62
Linings are used on the interior of pipelines to

  • A. reduce magnetic polarity.
  • B. provide protection against soil chemicals.
  • C. afford limited temperature insulation.
  • D. protect the transported product.

Answer: D


NEW QUESTION # 63
Which type of pipelines collect the gas from the transmission system so utility companies can distribute the gas to end users?

  • A. Gathering
  • B. Midstream
  • C. Distribution
  • D. Transmission

Answer: C


NEW QUESTION # 64
Centrifugal blast cleaning requires:

  • A. The use of single use abrasives
  • B. A large volume of air to propel the abrasive
  • C. Very large nozzles
  • D. Well maintained blast wheels

Answer: D


NEW QUESTION # 65
You are the NACE Inspector on a project where a stationary floating structure is being coated and you notice a self-smoothing anti-fouling coating has been specified.
This is not a good choice because:

  • A. It contains biocide
  • B. The floating structure is stationary
  • C. It doesn't contain biocide
  • D. It will result in a very slippery surface

Answer: A


NEW QUESTION # 66
Coating surveys may include which steps?
Select All That Apply:

  • A. Schedule the remedial work
  • B. Summarize the collected data
  • C. Evaluate the coatings performance
  • D. Develop a survey plan

Answer: A,B,C,D


NEW QUESTION # 67
On pipelines, which coating is identifiable by its distinct colors, usually light blue, green, or grey?

  • A. Heat-shrink sleeves
  • B. Liquid epoxies
  • C. Concrete
  • D. Coal Tar Enamel

Answer: B


NEW QUESTION # 68
As a NACE Level 2 Inspector on a field job; prior to submission your documentation should always reviewed and approved by:

  • A. A NACE Level 1 Inspector
  • B. Another NACE Level 2 Inspector
  • C. A NACE Protective Coating Specialist
  • D. A NACE Level 3 Inspector

Answer: D


NEW QUESTION # 69
Steel shot grit contaminated with oil or grease used in a cetrifugal blast cleaning should be

  • A. washed with clean potable water prior to Use.
  • B. disposed of properly.
  • C. run through the air wash separator.
  • D. mixed with uncontaminated abrasive

Answer: B


NEW QUESTION # 70
You are a NACE Level 2 Coating Inspector who has just arrived on a job in progress where there is no Inspection and Test Plan (ITP). The first morning you arrive the job is behind schedule and you are asked to take DIY Film Thickness readings.
Your FIRST preferred course of action is to:

  • A. Call your supervisor
  • B. Develop your own methodology and proceed take the readings
  • C. Refuse to take readings until an is in place
  • D. Use a generally accepted industry standard and to take readings

Answer: D


NEW QUESTION # 71
......

NACE-CIP2-001 Exam Dumps, NACE-CIP2-001 Practice Test Questions: https://www.exam4labs.com/NACE-CIP2-001-practice-torrent.html

Free NACE-CIP2-001 Exam Dumps to Pass Exam Easily: https://drive.google.com/open?id=1zWs9iaNEf9ef4aLHG7xGRYVCKpEKYmhm