[Dec-2024] Check your preparation for EMC D-SNC-DY-00 On-Demand Exam
Practice Exam D-SNC-DY-00 Realistic Dumps Verified Questions
EMC D-SNC-DY-00 Exam Syllabus Topics:
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
NEW QUESTION # 20
What does show interface breakout port slot/slot command display?
- A. The configuration of that port
- B. The In Progress/Complete status of the breakout of the port
- C. The Error/Debug status of the breakout of the port
- D. The breakout modes available to that port
Answer: D
Explanation:
The show interface breakout port slot/slot command displays the breakout modes available for the specified port. Breakout modes determine how a single high-speed port can be split into multiple lower-speed ports, providing flexibility in network port configurations.
References:
* Dell Technologies SONiC Command Reference Guide
* Port Breakout Configuration Guide
NEW QUESTION # 21
Which protocol is used to perform an automated installation of Enterprise SONiC?
- A. HTTP
- B. SCP
- C. SFTP
Answer: A
Explanation:
The automated installation of Enterprise SONiC is typically performed using the HTTP protocol. During the Zero Touch Provisioning (ZTP) process, the switch retrieves configuration files and software images from an HTTP server, allowing for automated and streamlined deployments.
References:
* Dell Technologies SONiC documentation
* ONIE User Guide
NEW QUESTION # 22
What two methods can be used to upgrade or downgrade Enterprise SONiC?
- A. Boot Loader
- B. MF-CLI
- C. GRUB
- D. SONiC-CLI
Answer: A,C
Explanation:
Enterprise SONiC can be upgraded or downgraded using:
* Boot Loader (A): The boot loader can be used to select and load different versions of the SONiC firmware.
* GRUB (D): GRUB (Grand Unified Bootloader) is another method used to manage and select different SONiC firmware versions during system boot-up.
References:
* Dell Technologies SONiC documentation
* SONiC Upgrade Guide
NEW QUESTION # 23
Enterprise SONiC Switch 1 and Switch 2 are part of a symmetric VXLAN fabric in a data center environment.
Switch 1 has learned MAC addresses from its local VLANs.
What role does BGP EVPN play in this scenario?
- A. Enables efficient communication across the VXLAN fabric
- B. Distributes locally learned MAC addresses to Switch 2
- C. Establishes Layer 2 connectivity between Switch 1 and Switch 2
Answer: B
Explanation:
BGP EVPN (Border Gateway Protocol Ethernet VPN) is used in a VXLAN fabric to distribute MAC address reachability information between switches. In this scenario, Switch 1 uses BGP EVPN to advertise the locally learned MAC addresses to Switch 2. This distribution of MAC addresses enables the switches to build and maintain an efficient forwarding table, facilitating communication across the VXLAN fabric.
References:
* Dell Technologies SONiC documentation
* BGP EVPN Configuration Guide
NEW QUESTION # 24
Use the simulator to perform the following configuration task.
1. Map a single-tagged CVLAN 100 to SVLAN 200 translation on PE
switch interface Eth1/1.
2. Map a double-tagged VLAN packet with an outer CVLAN 100 and an
inner dot1q 200 to SVLAN 300 translation on PE switch interface
Eth1/2.
The necessary VLANs and VLAN stacking have already been configured.
Answer:
Explanation:
see the explanation for all step by step solution with all explanation.
Explanation:
Here are the steps to configure the required VLAN translations on a Dell SONiC switch:
* Map a Single-Tagged CVLAN 100 to SVLAN 200 on Interface Eth1/1:
sonic# configure terminal
sonic(config)# interface Ethernet1/1
sonic(config-if-Ethernet1/1)# switchport mode trunk
sonic(config-if-Ethernet1/1)# switchport vlan mapping 100 200
sonic(config-if-Ethernet1/1)# end
sonic# write memory
* Map a Double-Tagged VLAN Packet with Outer CVLAN 100 and Inner dot1q 200 to SVLAN 300 on Interface Eth1/2:
sonic# configure terminal
sonic(config)# interface Ethernet1/2
sonic(config-if-Ethernet1/2)# switchport mode trunk
sonic(config-if-Ethernet1/2)# switchport vlan mapping 100 200 300
sonic(config-if-Ethernet1/2)# end
sonic# write memory
Comprehensive Detailed Step by Step Explanation with References:
* Enter Configuration Mode:
* Access the global configuration mode using the configure terminal command.
* Configure Interface Eth1/1:
* Enter interface configuration mode for Ethernet1/1 using the command interface Ethernet1/1.
* Set the switchport mode to trunk with the command switchport mode trunk.
* Configure the VLAN translation using the switchport vlan mapping 100 200 command, which maps CVLAN 100 to SVLAN 200.
* Exit the interface configuration mode by typing end.
* Save the configuration with write memory.
* Configure Interface Eth1/2:
* Enter interface configuration mode for Ethernet1/2 using the command interface Ethernet1/2.
* Set the switchport mode to trunk with the command switchport mode trunk.
* Configure the double-tagged VLAN translation using the switchport vlan mapping 100 200 300 command, which maps packets with outer CVLAN 100 and inner dot1q 200 to SVLAN 300.
* Exit the interface configuration mode by typing end.
* Save the configuration with write memory.
References:
* Dell Technologies Networking - SONiC
* Dell Enterprise SONiC Deployment Guide
These steps provide a comprehensive guide to configure VLAN translations on a Dell SONiC switch, ensuring that the specific requirements for single-tagged and double-tagged VLAN mappings are met.
NEW QUESTION # 25
Refer to the exhibit.
What is the primary VRRP router for VRRP group 10?
- A. Router-3
- B. Router-1
- C. Router-2
Answer: C
Explanation:
Based on the exhibit, Router-2 has the highest priority (90) in VRRP group 10. In VRRP, the router with the highest priority becomes the primary (master) router. Therefore, Router-2 is the primary VRRP router for VRRP group 10.
References:
* Dell Technologies SONiC VRRP Configuration Guide
* VRRP Protocol Overview
NEW QUESTION # 26
A deployment requires routing and dynamic access control lists. What bundle must be used for this deployment?
- A. Enterprise Standard
- B. Edge Standard
- C. Cloud Premium
- D. Enterprise Standard
Answer: A
Explanation:
For a deployment that requires routing and dynamic access control lists, the appropriate bundle to use is the Enterprise Standard bundle. This bundle includes advanced routing capabilities and supports dynamic access control lists for comprehensive network management and security.
References:
* Dell Technologies SONiC documentation
* Dell Networking Bundle Configuration Guide
NEW QUESTION # 27
In what order should these commands be entered to configure an access port in SONiC CLI if the required VLAN is already configured?
Answer:
Explanation:
Explanation:
To configure an access port on the SONiC CLI, the commands should be entered in the following order:
* Enter global configuration mode with configure terminal.
* Specify the interface to configure using interface ethernet 1/1.
* Set the interface to access mode and assign it to VLAN 20 with switchport access vlan 20.
* Exit the interface configuration mode with exit.
References:
* Dell Technologies SONiC Command Reference Guide
* Dell Networking Configuration Guide
NEW QUESTION # 28
A customer must configure a peer link between two switches in the L2 MC-LAG scenario.
SwitchB has already been configured. Configure the peer link on SwitchA.
Use the following configuration information:
MC-LAG domain 1
VLAN 101
Peer link Port-Channel 100
SwitchA IP: 192.168.1.1/24
SwitchB IP: 192.168.1.2/24
MC-LAG system MAC: 00:00:00:11:11:11
The physical ports to connect the peer switch are Eth 1/5 and Eth 1/6 for each switch.

Answer:
Explanation:
see the explanation for all step by step solution with all explanation.
Explanation:
Here are the steps to configure the peer link on SwitchA:
* Enter Configuration Mode:
SwitchA# configure terminal
* Create VLAN 101:
SwitchA(config)# vlan 101
* Create Port-Channel 100:
SwitchA(config)# interface port-channel 100
SwitchA(config-if-po100)# switchport mode trunk
SwitchA(config-if-po100)# switchport trunk allowed vlan 101
SwitchA(config-if-po100)# exit
* Assign Physical Interfaces to Port-Channel 100:
SwitchA(config)# interface ethernet 1/5
SwitchA(config-if-eth1/5)# channel-group 100 mode active
SwitchA(config-if-eth1/5)# exit
SwitchA(config)# interface ethernet 1/6
SwitchA(config-if-eth1/6)# channel-group 100 mode active
SwitchA(config-if-eth1/6)# exit
* Configure MC-LAG Domain 1:
SwitchA(config)# mclag domain 1
SwitchA(config-mclag-domain)# peer-link port-channel 100
SwitchA(config-mclag-domain)# local-ip 192.168.1.1
SwitchA(config-mclag-domain)# peer-ip 192.168.1.2
SwitchA(config-mclag-domain)# system-mac 00:00:00:11:11:11
SwitchA(config-mclag-domain)# exit
* Save Configuration:
SwitchA# write memory
Comprehensive Detailed Step by Step Explanation with References:
* Enter Configuration Mode:
* Begin by entering the global configuration mode to make changes to the switch configuration.
* Create VLAN 101:
* Create VLAN 101 to be used for the MC-LAG peer link communication.
* Create Port-Channel 100:
* Enter the port channel interface configuration mode using interface port-channel 100.
* Set the port channel to trunk mode with switchport mode trunk.
* Allow VLAN 101 on the trunk with switchport trunk allowed vlan 101.
* Exit the port channel interface configuration mode.
* Assign Physical Interfaces to Port-Channel 100:
* Enter interface configuration mode for ethernet 1/5 and assign it to port channel 100 using the channel-group 100 mode active command.
* Exit the interface configuration mode.
* Repeat the same steps for ethernet 1/6.
* Configure MC-LAG Domain 1:
* Enter the MC-LAG domain configuration mode using mclag domain 1.
* Specify the peer link port channel with peer-link port-channel 100.
* Configure the local IP address as 192.168.1.1 using local-ip 192.168.1.1.
* Configure the peer IP address as 192.168.1.2 using peer-ip 192.168.1.2.
* Set the MC-LAG system MAC address using system-mac 00:00:00:11:11:11.
* Exit the MC-LAG domain configuration mode.
* Save Configuration:
* Save the configuration to ensure the changes persist after a reboot using the write memory command.
References:
* Dell Technologies Networking - SONiC
* Dell Enterprise SONiC Deployment Guide
These steps provide a comprehensive guide to configure the peer link for an MC-LAG scenario on SwitchA, ensuring the specific requirements for IP addressing, VLAN configuration, and port channel setup are met.
NEW QUESTION # 29
How many port channels can be assigned to a single port?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: B
Explanation:
According to the Dell SONiC documentation, a single physical port can be a member of only one port channel at a time. This restriction ensures the consistency and integrity of link aggregation configurations.
References:
* Dell Networking SONiC: How to Configure Port Channels
* Dell Technologies InfoHub
NEW QUESTION # 30
Refer to the exhibit.
What can be determined from this show command?
- A. There is a 10% probability that traffic is marked as congested
- B. ECN is enabled for all colors
- C. ECN is enabled for all DSCP values
- D. Traffic below 100 KB is marked as congested
Answer: B
Explanation:
The output of the command show qos wred-policy pfc34 shows the ECN (Explicit Congestion Notification) configuration for the policy pfc34. The line ecn: ecn_all indicates that ECN is enabled for all traffic classes (all DSCP values). Additionally, the green-min-threshold, green-max-threshold, and green-drop-probability settings are shown, but there is no indication of a 10% probability for marking traffic as congested. Therefore, the correct answer is B.
References:
* Dell Enterprise SONiC documentation
* Dell Technologies InfoHub
NEW QUESTION # 31
What is an iBGP neighbor relationship?
- A. Two BGP neighbors share L2VPN EVPN advertisements.
- B. Two BGP neighbors share only private networks.
- C. Two BGP neighbors share only native BGP networks.
- D. Two BGP neighbors have the same autonomous system numbers
Answer: D
Explanation:
An iBGP (Internal Border Gateway Protocol) neighbor relationship is established between two BGP routers within the same autonomous system (AS). This relationship allows for the exchange of routing information within the AS, ensuring that internal routes are propagated correctly.
References:
* Dell Technologies SONiC Routing Guide
* BGP Configuration Guide
NEW QUESTION # 32
An administrator for a service provider uses this command on a switch:
What is the result of running the command?
- A. Maps the VLAN traffic that a CVLAN identifies to a VNI on a VTEP
- B. Maps the VLAN traffic that an SVLAN identifies to a VNI on a VTEP
- C. Maps the VLAN traffic that a TPID identifies to a VNI on a VTEP
Answer: B
Explanation:
The command interface vxlan vtep-stacking followed by map vni 10010 vlan 100 maps the VLAN traffic that an SVLAN identifies to a VNI on a VTEP. In this context, SVLAN (Service VLAN) is being mapped to a VXLAN Network Identifier (VNI) for encapsulation and transport across the VXLAN tunnel.
References:
* Dell Technologies SONiC documentation
* VXLAN Configuration Guide
NEW QUESTION # 33
What interface must be selected when configuring the management port from within the MF-CLI environment?
- A. ma 0/1
- B. mgmt 1/1/1
- C. eth0
- D. Management 0
Answer: C
Explanation:
* Dell SONiC Management Interface Configuration:
* In Dell SONiC, the management port configuration is a crucial aspect that allows administrators to access and manage the network device.
* The management interface typically provides out-of-band management access to the device, ensuring that even if the data network is down, the management network can still be accessed.
* Common Interface Naming Conventions:
* mgmt 1/1/1: This naming convention is not typically used in Dell SONiC environments for management interfaces.
* ma 0/1: This could be a potential naming convention but is not standard for Dell SONiC.
* Management 0: This is a logical name but does not align with the standard interface naming conventions used in Dell SONiC.
* eth0: This is the standard naming convention used for the primary management interface in most Linux-based systems, including Dell SONiC.
* Verification with Dell SONiC Documentation:
* Dell SONiC documentation specifies that the management interface is usually named eth0.
* When accessing the management interface within the MF-CLI (Management Framework Command Line Interface) environment, eth0 is the correct interface to configure.
* Practical Configuration Example:
* When configuring the management port, the command might look something like:
config interface ip add eth0 <management_ip_address>/<subnet_mask>
* This command specifies the management interface eth0 and assigns it an IP address for network management purposes.
References:
* Dell Enterprise SONiC Deployment Guide
* Dell Technologies Networking - SONiC
This detailed step-by-step explanation confirms that the correct answer is D, providing insights into the typical interface naming conventions and configuration practices within the Dell SONiC environment.
NEW QUESTION # 34
Which two elements are configured when RoCE is enabled?
- A. ETS
- B. TCP
- C. IB
- D. PFC
Answer: A,D
Explanation:
When RDMA over Converged Ethernet (RoCE) is enabled, Enhanced Transmission Selection (ETS) and Priority Flow Control (PFC) are two key elements that need to be configured. ETS allows for bandwidth allocation among different traffic classes, and PFC provides lossless Ethernet operation for specific traffic classes to support low-latency, high-performance network communication.
References:
* Dell Technologies SONiC documentation
* RDMA over Converged Ethernet Configuration Guide
NEW QUESTION # 35
What is ECMP?
- A. A routing protocol with multipath support
- B. A round-robin path distribution mechanism
- C. A routing protocol database filter supporting a maximum of four paths
- D. A Layer 3 routing feature to forward traffic using multiple available paths
Answer: D
Explanation:
ECMP (Equal-Cost Multi-Path) is a Layer 3 routing feature that allows traffic to be forwarded using multiple available paths of equal cost. This improves bandwidth utilization and provides redundancy. ECMP is commonly used in modern networks to optimize the flow of traffic and increase the resiliency of network connections.
References:
* Dell Technologies SONiC documentation
* ECMP Configuration Guide
NEW QUESTION # 36
Which network devices route unencapsulated user traffic in a symmetric IRB overlay network?
- A. Capability extended next hop router and leaf router
- B. Leaf router and spine router
- C. Source VTEP and destination VTEP
- D. Autonomous system boundary router and source VTEP
Answer: C
Explanation:
In a symmetric Integrated Routing and Bridging (IRB) overlay network, the Source Virtual Tunnel End Point (VTEP) and the Destination VTEP route unencapsulated user traffic. Symmetric IRB ensures that routing occurs at both the ingress and egress VTEPs, allowing for optimized traffic flow and efficient network operations.
References:
* Dell Technologies SONiC documentation
* VXLAN Configuration Guide
NEW QUESTION # 37
What is a correct use-case scenario for ZTP in Enterprise SONiC?
- A. The user wants to configure the switch manually using the CLI.
- B. The user wants single pane of glass monitoring.
- C. The user wants multivendor switch deployment.
- D. The user wants to replace a failed unit and use an automatic script.
Answer: D
NEW QUESTION # 38
Which two things does the no vrrp 100 address-family ipv6 command delete?
- A. Address-family
- B. Version
- C. Identifier
- D. Authentication
- E. Interface
Answer: A,C
Explanation:
The no vrrp 100 address-family ipv6 command deletes the VRRP (Virtual Router Redundancy Protocol) identifier (A) and the address-family configuration (D) for VRRP group 100. This effectively removes the VRRP configuration for the specified address family.
References:
* Dell Technologies SONiC documentation
* VRRP Configuration Guide
NEW QUESTION # 39
......