100% Real D-SNC-DY-00 dumps - Brilliant D-SNC-DY-00 Exam Questions PDF [Q15-Q31]

Share

100% Real D-SNC-DY-00 dumps  - Brilliant D-SNC-DY-00 Exam Questions PDF

D-SNC-DY-00 Exam PDF [2024] Tests Free Updated Today with Correct 47 Questions


EMC D-SNC-DY-00 Exam Syllabus Topics:

TopicDetails
Topic 1
  • SONiC Installation: Your proficiency in SONiC installation, upgrade, and downgrade methods will be tested in this Dell EMC D-SNC-DY-00 exam topic. You will need to install SONiC using both the ONIE manual and automatic methods. This topic measures your hands-on skills in managing SONiC installations efficiently.
Topic 2
  • QoS: Your understanding of Quality of Service (QoS) is essential to become a certified Dell cloud engineer. The exam evaluates your ability to configure and verify QoS features. This section tests your ability to ensure optimal network performance, a vital skill in managing cloud environments where service quality is paramount.
Topic 3
  • VXLAN: This topic focuses on your ability to manage VXLAN operations, including configuring and verifying BGP EVPN with both Asymmetric and Symmetric IRB. Understanding VXLAN is essential for enabling scalable and efficient cloud networks, making this topic critical to your D-SNC-DY-00 exam success.
Topic 4
  • SONiC Configuration: This comprehensive topic evaluates your ability to administer and configure critical network components. You will need to manage port groups, configure management access, handle VLANs, and verify advanced features like Link Aggregation Groups and MC-LAG. Proficiency in these Dell EMC D-SNC-DY-00 exam areas is crucial for ensuring robust and scalable network operations.

 

NEW QUESTION # 15
Which network devices route unencapsulated user traffic in a symmetric IRB overlay network?

  • A. Autonomous system boundary router and source VTEP
  • B. Capability extended next hop router and leaf router
  • C. Leaf router and spine router
  • D. Source VTEP and destination VTEP

Answer: D

Explanation:
In a symmetric Integrated Routing and Bridging (IRB) overlay network, the Source Virtual Tunnel End Point (VTEP) and the Destination VTEP route unencapsulated user traffic. Symmetric IRB ensures that routing occurs at both the ingress and egress VTEPs, allowing for optimized traffic flow and efficient network operations.
References:
* Dell Technologies SONiC documentation
* VXLAN Configuration Guide


NEW QUESTION # 16
What is an iBGP neighbor relationship?

  • A. Two BGP neighbors have the same autonomous system numbers
  • B. Two BGP neighbors share L2VPN EVPN advertisements.
  • C. Two BGP neighbors share only private networks.
  • D. Two BGP neighbors share only native BGP networks.

Answer: A

Explanation:
An iBGP (Internal Border Gateway Protocol) neighbor relationship is established between two BGP routers within the same autonomous system (AS). This relationship allows for the exchange of routing information within the AS, ensuring that internal routes are propagated correctly.
References:
* Dell Technologies SONiC Routing Guide
* BGP Configuration Guide


NEW QUESTION # 17
Refer to the exhibits.


PC1 has a valid address on the 192.168.10.0 network, and PC2 has a valid address on the 192.168.20.0 network.
What happens when a ping command is issued between PC1 and PC2?

  • A. The ping is unsuccessful because there is no route to the VLAN 10 gateway address of 192.168.10.254.
  • B. The ping is successful because there is a route to 10.0.1.1, which is connected to 1(10.2.2, which is connected to PC2.
  • C. The ping is successful because there are two routes from switch1 to switch2 which are connected to PC2.
  • D. The ping is unsuccessful because there is no route from switch 1 to the 192.168.20.0 network.

Answer: D

Explanation:
* Network Topology Analysis:
* PC1 is on VLAN 10 with an IP address in the 192.168.10.0/24 subnet.
* PC2 is on VLAN 20 with an IP address in the 192.168.20.0/24 subnet.
* The network uses OSPF for routing between the switches.
* The OSPF area is 0, and all switches have loopback interfaces for OSPF.
* Routing Table Examination (from switch1):
* The show ip route command output from switch1 provides a detailed look at the routing table.
* Routes to the 192.168.10.0/24 network (directly connected via Vlan10) are present.
* No routes to the 192.168.20.0/24 network are listed in switch1's routing table.
* Explanation:
* For PC1 to communicate with PC2, switch1 must have a route to the 192.168.20.0/24 network.
* The absence of a route to the 192.168.20.0/24 network in switch1's routing table means that switch1 cannot forward packets destined for 192.168.20.0/24.
* Therefore, any ping from PC1 to PC2 will be unsuccessful as switch1 does not know how to route packets to PC2's network.
* Verification with Dell SONiC:
* In Dell SONiC environments, OSPF is configured to ensure dynamic routing.
* The configuration must include all necessary networks for inter-switch routing.
* If a network (like 192.168.20.0/24) is not included in OSPF configurations on switch1, routes to that network will not be advertised or learned, leading to failed connectivity tests like the ping from PC1 to PC2.
References:
* Dell Enterprise SONiC Deployment Guide
* Dell Technologies Networking - SONiC


NEW QUESTION # 18
Refer to the exhibit.

The router ID has not been manually configured. What router ID is used for Switch 3?

  • A. 10.0.2.1
  • B. 192.168.100.2
  • C. 10.0.1.1
  • D. 192.168.100.0

Answer: C

Explanation:
In the absence of a manually configured router ID, OSPF typically uses the highest IP address on the switch's active interfaces. For Switch 3 in the exhibit, the highest IP address is 10.0.1.1 on Loopback 0. Therefore,
10.0.1.1 is used as the router ID for Switch 3.
References:
* Dell Technologies SONiC documentation
* OSPF Configuration Guide


NEW QUESTION # 19
What are two characteristics of route maps in Enterprise SONIC?

  • A. They are a series of commands that contain a matching criterion and action.
  • B. Route-map names are not case-sensitive.
  • C. The permit or deny clause In route maps permits or rejects the matching routes from being redistributed.
  • D. Each route map clause has the type values of Match. Set. and Act.

Answer: A,C

Explanation:
Route maps in Enterprise SONIC are used for controlling and modifying routing information. They contain a series of commands with matching criteria and actions. The permit or deny clause within route maps determines whether the matching routes are permitted or denied from being redistributed.
References:
* Dell Technologies SONiC Route Map Configuration Guide
* Dell Networking Configuration Guide


NEW QUESTION # 20
What two methods can be used to upgrade or downgrade Enterprise SONiC?

  • A. SONiC-CLI
  • B. GRUB
  • C. Boot Loader
  • D. MF-CLI

Answer: B,C

Explanation:
Enterprise SONiC can be upgraded or downgraded using:
* Boot Loader (A): The boot loader can be used to select and load different versions of the SONiC firmware.
* GRUB (D): GRUB (Grand Unified Bootloader) is another method used to manage and select different SONiC firmware versions during system boot-up.
References:
* Dell Technologies SONiC documentation
* SONiC Upgrade Guide


NEW QUESTION # 21
Create port channel 10 on interfaces Eth 1/11 and 1/12, so that it connects to an already configured switch. A server will be connected on Eth 1/1. Both the server and port channel need VLAN 1 untagged and only VLAN
10 tagged.
Complete the configuration on Switch A.

Answer:

Explanation:
see the explanation for all step by step solution with all explanation.
Explanation:
Here are the steps to configure the required port channel and VLAN settings on Switch A:
* Enter Configuration Mode:
SwitchA# configure terminal
* Create Port Channel 10:
SwitchA(config)# interface port-channel 10
SwitchA(config-if-po10)# switchport mode trunk
SwitchA(config-if-po10)# switchport trunk native vlan 1
SwitchA(config-if-po10)# switchport trunk allowed vlan 1,10
* Assign Interfaces Eth 1/11 and Eth 1/12 to Port Channel 10:
SwitchA(config)# interface ethernet 1/11
SwitchA(config-if-eth1/11)# channel-group 10 mode active
SwitchA(config-if-eth1/11)# exit
SwitchA(config)# interface ethernet 1/12
SwitchA(config-if-eth1/12)# channel-group 10 mode active
SwitchA(config-if-eth1/12)# exit
* Configure Interface Eth 1/1 for Server Connection:
SwitchA(config)# interface ethernet 1/1
SwitchA(config-if-eth1/1)# switchport mode trunk
SwitchA(config-if-eth1/1)# switchport trunk native vlan 1
SwitchA(config-if-eth1/1)# switchport trunk allowed vlan 1,10
SwitchA(config-if-eth1/1)# end
* Save Configuration:
SwitchA# write memory
Comprehensive Detailed Step by Step Explanation with References:
* Enter Configuration Mode:
* Start by entering the global configuration mode to make changes to the switch configuration.
* Create Port Channel 10:
* Enter the port channel interface configuration mode using interface port-channel 10.
* Set the port channel to trunk mode with switchport mode trunk.
* Specify VLAN 1 as the native VLAN (untagged) using switchport trunk native vlan 1.
* Allow VLANs 1 and 10 on the trunk with switchport trunk allowed vlan 1,10.
* Assign Interfaces Eth 1/11 and Eth 1/12 to Port Channel 10:
* Enter interface configuration mode for ethernet 1/11 and ethernet 1/12.
* Assign each interface to port channel 10 using the channel-group 10 mode active command.
* Exit the interface configuration mode.
* Configure Interface Eth 1/1 for Server Connection:
* Enter interface configuration mode for ethernet 1/1.
* Set the interface to trunk mode with switchport mode trunk.
* Specify VLAN 1 as the native VLAN using switchport trunk native vlan 1.
* Allow VLANs 1 and 10 on the trunk with switchport trunk allowed vlan 1,10.
* Exit the configuration mode.
* Save Configuration:
* Ensure the configuration is saved so it persists after a reboot using the write memory command.
References:
* Dell Technologies Networking - SONiC
* Dell Enterprise SONiC Deployment Guide
These steps provide a comprehensive guide to configure a port channel and VLAN settings on Switch A to meet the specified requirements for server and trunk connections.


NEW QUESTION # 22
Refer to the exhibit.

The route distinguisher was autogenerated. Which VLAN is mapped to VNI410?

  • A. VLAN 26
  • B. VLAN 410
  • C. VLAN41
  • D. VLAN 10

Answer: D

Explanation:
The route distinguisher (RD) in the exhibit is 10.0.2.26:41. The RD typically reflects the VNI and VLAN mapping configuration. Given that the VNI is 410 and the RD ends with :41, it implies that VLAN 10 is mapped to VNI 410.
References:
* Dell Technologies SONiC documentation
* VXLAN Configuration Guide


NEW QUESTION # 23
How many port channels can be assigned to a single port?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D

Explanation:
According to the Dell SONiC documentation, a single physical port can be a member of only one port channel at a time. This restriction ensures the consistency and integrity of link aggregation configurations.
References:
* Dell Networking SONiC: How to Configure Port Channels
* Dell Technologies InfoHub


NEW QUESTION # 24
Refer to the exhibit.

What is the purpose of the static route?

  • A. Verify that the 12.0.0.0 network is active and reachable.
  • B. Verify that devices in VLAN 45 are reachable.
  • C. Provide a route to the 192.168.45.0 network.
  • D. Provide a route to the 12.0.0.0 network.

Answer: D

Explanation:
The static route shown in the exhibit S* 12.0.0.0/16 via 192.168.45.254 Vlan45 is used to provide a route to the 12.0.0.0 network. This static route directs traffic destined for the 12.0.0.0/16 network through the gateway at 192.168.45.254, which is associated with VLAN 45. This configuration is typically used to ensure that traffic can reach a specific network via a defined path.
References:
* Dell Technologies SONiC Routing Guide
* Dell Networking Configuration Guide


NEW QUESTION # 25
Use the simulator to perform the following configuration task.
1. Map a single-tagged CVLAN 100 to SVLAN 200 translation on PE
switch interface Eth1/1.
2. Map a double-tagged VLAN packet with an outer CVLAN 100 and an
inner dot1q 200 to SVLAN 300 translation on PE switch interface
Eth1/2.
The necessary VLANs and VLAN stacking have already been configured.

Answer:

Explanation:
see the explanation for all step by step solution with all explanation.
Explanation:
Here are the steps to configure the required VLAN translations on a Dell SONiC switch:
* Map a Single-Tagged CVLAN 100 to SVLAN 200 on Interface Eth1/1:
sonic# configure terminal
sonic(config)# interface Ethernet1/1
sonic(config-if-Ethernet1/1)# switchport mode trunk
sonic(config-if-Ethernet1/1)# switchport vlan mapping 100 200
sonic(config-if-Ethernet1/1)# end
sonic# write memory
* Map a Double-Tagged VLAN Packet with Outer CVLAN 100 and Inner dot1q 200 to SVLAN 300 on Interface Eth1/2:
sonic# configure terminal
sonic(config)# interface Ethernet1/2
sonic(config-if-Ethernet1/2)# switchport mode trunk
sonic(config-if-Ethernet1/2)# switchport vlan mapping 100 200 300
sonic(config-if-Ethernet1/2)# end
sonic# write memory
Comprehensive Detailed Step by Step Explanation with References:
* Enter Configuration Mode:
* Access the global configuration mode using the configure terminal command.
* Configure Interface Eth1/1:
* Enter interface configuration mode for Ethernet1/1 using the command interface Ethernet1/1.
* Set the switchport mode to trunk with the command switchport mode trunk.
* Configure the VLAN translation using the switchport vlan mapping 100 200 command, which maps CVLAN 100 to SVLAN 200.
* Exit the interface configuration mode by typing end.
* Save the configuration with write memory.
* Configure Interface Eth1/2:
* Enter interface configuration mode for Ethernet1/2 using the command interface Ethernet1/2.
* Set the switchport mode to trunk with the command switchport mode trunk.
* Configure the double-tagged VLAN translation using the switchport vlan mapping 100 200 300 command, which maps packets with outer CVLAN 100 and inner dot1q 200 to SVLAN 300.
* Exit the interface configuration mode by typing end.
* Save the configuration with write memory.
References:
* Dell Technologies Networking - SONiC
* Dell Enterprise SONiC Deployment Guide
These steps provide a comprehensive guide to configure VLAN translations on a Dell SONiC switch, ensuring that the specific requirements for single-tagged and double-tagged VLAN mappings are met.


NEW QUESTION # 26
What does show interface breakout port slot/slot command display?

  • A. The configuration of that port
  • B. The In Progress/Complete status of the breakout of the port
  • C. The breakout modes available to that port
  • D. The Error/Debug status of the breakout of the port

Answer: C

Explanation:
The show interface breakout port slot/slot command displays the breakout modes available for the specified port. Breakout modes determine how a single high-speed port can be split into multiple lower-speed ports, providing flexibility in network port configurations.
References:
* Dell Technologies SONiC Command Reference Guide
* Port Breakout Configuration Guide


NEW QUESTION # 27
Which two elements are configured when RoCE is enabled?

  • A. ETS
  • B. TCP
  • C. PFC
  • D. IB

Answer: A,C

Explanation:
When RDMA over Converged Ethernet (RoCE) is enabled, Enhanced Transmission Selection (ETS) and Priority Flow Control (PFC) are two key elements that need to be configured. ETS allows for bandwidth allocation among different traffic classes, and PFC provides lossless Ethernet operation for specific traffic classes to support low-latency, high-performance network communication.
References:
* Dell Technologies SONiC documentation
* RDMA over Converged Ethernet Configuration Guide


NEW QUESTION # 28
A customer must configure a peer link between two switches in the L2 MC-LAG scenario.
SwitchB has already been configured. Configure the peer link on SwitchA.
Use the following configuration information:
MC-LAG domain 1
VLAN 101
Peer link Port-Channel 100
SwitchA IP: 192.168.1.1/24
SwitchB IP: 192.168.1.2/24
MC-LAG system MAC: 00:00:00:11:11:11
The physical ports to connect the peer switch are Eth 1/5 and Eth 1/6 for each switch.

Answer:

Explanation:
see the explanation for all step by step solution with all explanation.
Explanation:
Here are the steps to configure the peer link on SwitchA:
* Enter Configuration Mode:
SwitchA# configure terminal
* Create VLAN 101:
SwitchA(config)# vlan 101
* Create Port-Channel 100:
SwitchA(config)# interface port-channel 100
SwitchA(config-if-po100)# switchport mode trunk
SwitchA(config-if-po100)# switchport trunk allowed vlan 101
SwitchA(config-if-po100)# exit
* Assign Physical Interfaces to Port-Channel 100:
SwitchA(config)# interface ethernet 1/5
SwitchA(config-if-eth1/5)# channel-group 100 mode active
SwitchA(config-if-eth1/5)# exit
SwitchA(config)# interface ethernet 1/6
SwitchA(config-if-eth1/6)# channel-group 100 mode active
SwitchA(config-if-eth1/6)# exit
* Configure MC-LAG Domain 1:
SwitchA(config)# mclag domain 1
SwitchA(config-mclag-domain)# peer-link port-channel 100
SwitchA(config-mclag-domain)# local-ip 192.168.1.1
SwitchA(config-mclag-domain)# peer-ip 192.168.1.2
SwitchA(config-mclag-domain)# system-mac 00:00:00:11:11:11
SwitchA(config-mclag-domain)# exit
* Save Configuration:
SwitchA# write memory
Comprehensive Detailed Step by Step Explanation with References:
* Enter Configuration Mode:
* Begin by entering the global configuration mode to make changes to the switch configuration.
* Create VLAN 101:
* Create VLAN 101 to be used for the MC-LAG peer link communication.
* Create Port-Channel 100:
* Enter the port channel interface configuration mode using interface port-channel 100.
* Set the port channel to trunk mode with switchport mode trunk.
* Allow VLAN 101 on the trunk with switchport trunk allowed vlan 101.
* Exit the port channel interface configuration mode.
* Assign Physical Interfaces to Port-Channel 100:
* Enter interface configuration mode for ethernet 1/5 and assign it to port channel 100 using the channel-group 100 mode active command.
* Exit the interface configuration mode.
* Repeat the same steps for ethernet 1/6.
* Configure MC-LAG Domain 1:
* Enter the MC-LAG domain configuration mode using mclag domain 1.
* Specify the peer link port channel with peer-link port-channel 100.
* Configure the local IP address as 192.168.1.1 using local-ip 192.168.1.1.
* Configure the peer IP address as 192.168.1.2 using peer-ip 192.168.1.2.
* Set the MC-LAG system MAC address using system-mac 00:00:00:11:11:11.
* Exit the MC-LAG domain configuration mode.
* Save Configuration:
* Save the configuration to ensure the changes persist after a reboot using the write memory command.
References:
* Dell Technologies Networking - SONiC
* Dell Enterprise SONiC Deployment Guide
These steps provide a comprehensive guide to configure the peer link for an MC-LAG scenario on SwitchA, ensuring the specific requirements for IP addressing, VLAN configuration, and port channel setup are met.


NEW QUESTION # 29
Refer to the exhibit.

What can be determined from this show command?

  • A. Traffic below 100 KB is marked as congested
  • B. ECN is enabled for all DSCP values
  • C. ECN is enabled for all colors
  • D. There is a 10% probability that traffic is marked as congested

Answer: C

Explanation:
The output of the command show qos wred-policy pfc34 shows the ECN (Explicit Congestion Notification) configuration for the policy pfc34. The line ecn: ecn_all indicates that ECN is enabled for all traffic classes (all DSCP values). Additionally, the green-min-threshold, green-max-threshold, and green-drop-probability settings are shown, but there is no indication of a 10% probability for marking traffic as congested. Therefore, the correct answer is B.
References:
* Dell Enterprise SONiC documentation
* Dell Technologies InfoHub


NEW QUESTION # 30
What is a correct use-case scenario for ZTP in Enterprise SONiC?

  • A. The user wants multivendor switch deployment.
  • B. The user wants to replace a failed unit and use an automatic script.
  • C. The user wants single pane of glass monitoring.
  • D. The user wants to configure the switch manually using the CLI.

Answer: B


NEW QUESTION # 31
......

Verified & Correct D-SNC-DY-00 Practice Test Reliable Source Oct 23, 2024 Updated: https://www.exam4labs.com/D-SNC-DY-00-practice-torrent.html