NEW QUESTION 70
() air supply method must have a reasonable raised floor height.

  • A. Upper air duct air supply
  • B. Upper hood air supply
  • C. Row level horizontal air supply
  • D. Under the floor air supply

Answer: D

 

NEW QUESTION 71
When the NetCol5000-A removes the air conditioning humidifier, the steps to maintain the electrode humidifier include (). (Multiple choice)

  • A. Remove and clean the water supply valve
  • B. Replace the hardened and brittle hose thoroughly flush the drain
  • C. Disconnect the water supply valve and drain valve wiring
  • D. Remove the drain tank and drain valve component

Answer: A,B,C,D

 

NEW QUESTION 72
The NetCol5000-C has two installation scenarios with a chilled water distribution unit and no chilled water distribution unit.

  • A. True
  • B. False

Answer: A

 

NEW QUESTION 73
When the air conditioning outdoor of Huawei air-cooled air conditioner is installed horizontally, it is required to be ≥ () mm from the wall or obstacle.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A

 

NEW QUESTION 74
On the panel of the air conditioning unit, in the group control topology diagram, the difference between this machine and other machines is that there is a green border.

  • A. True
  • B. False

Answer: A

 

NEW QUESTION 75
The cabinet collector cannot be used for environmental data collection of IT cabinets.

  • A. False
  • B. True

Answer: A

 

NEW QUESTION 76
The PDU8000 intelligent power meter parameter display is abnormal, which may be caused by (). (Multiple choice)

  • A. Corresponding current transformer failure
  • B. The corresponding voltage collection line is abnormal.
  • C. Electricity or voltage ratio setting error
  • D. Intelligent power meter failure

Answer: A,B,C,D

 

NEW QUESTION 77
NeteCol can assign operational rights to user groups, or assign operational rights directly to users.

  • A. True
  • B. False

Answer: A

 

NEW QUESTION 78
When the integrated UPS is wired, if the input phase sequence is wrong, the machine will not work.

  • A. True
  • B. False

Answer: A

 

NEW QUESTION 79
What can be detected by the optional battery inspection instrument? (Multiple choice)

  • A. Frequency
  • B. Internal resistance
  • C. Voltage
  • D. Battery case temperature

Answer: B,C,D

 

NEW QUESTION 80
The following statement about the integration UP5000-E-120K-HASBS, which is wrong?

  • A. ATS does not support manual switching
  • B. Support smart battery management, adjustable battery sections
  • C. The energy statistics interface can display the energy of each output branch
  • D. Support the incoming line

Answer: A

 

NEW QUESTION 81
When a fire occurs in the FusionModule1000 box, the deflation indicator will show the words "Don't put in" to warn the site personnel not to enter the deflation zone.

  • A. True
  • B. False

Answer: A

 

NEW QUESTION 82
Smart ETH sockets support up to () cascading.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D

 

NEW QUESTION 83
In the NetCol5000-A air conditioner, if a large number of air bubbles are observed in the liquid crystal mirror, it indicates that the refrigerant system lacks refrigerant, and the refrigerant should be charged as needed.

  • A. True
  • B. False

Answer: A

 

NEW QUESTION 84
Which interface is not on the smart ETH socket?

  • A. PoE
  • B. AI/DI
  • C. PWR_OUT power cascade interface
  • D. PWR_IN power cascade interface

Answer: B

 

NEW QUESTION 85
When the NetCol5000-A air conditioner was commissioned, Which statement about the possible cause of the "exhaust high pressure alarm" was wrong?

  • A. Too little refrigerant charge
  • B. Excessive refrigerant charge
  • C. Outdoor fan cannot start
  • D. Outdoor unit fan speed is too low

Answer: A

 

NEW QUESTION 86
In the installation scenario where the indoor unit is higher than the outdoor unit, the oil trap must be set.

  • A. False
  • B. True

Answer: A

 

NEW QUESTION 87
The Netcol 5000-A35kW uses an electronic expansion valve.

  • A. False
  • B. True

Answer: A

 

NEW QUESTION 88
In the battery model 6-GFM-150, 150 indicates the battery ().

  • A. Maximum capacity
  • B. Rated capacity
  • C. Minimum capacity
  • D. Actual capacity

Answer: B

 

NEW QUESTION 89
......